| Size | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) |
|---|---|---|---|---|---|---|
| 2811 | 2.8 | 2.8 | 1.1 | 0.9 | 0.9 | |
| 2813 | 2.8 | 2.8 | 1.35 | 0.9 | 0.9 | |
| 3510 | 3.3 | 3.5 | 0.95 | 0.5 | 2.3 | 1.1 |
| 3816 | 3.8 | 3.8 | 1.65 | 1.3 | 1.2 | |
| 4818 | 4.8 | 4.8 | 1.8 | 1.6 | 1.6 | |
| 4828 | 4.8 | 4.8 | 2.8 | 1.6 | 1.6 | |
| 5818 | 5.8 | 5.8 | 1.8 | 1.9 | 2.0 | |
| 5828 | 5.8 | 5.8 | 2.8 | 1.9 | 2.0 | |
| 6823 | 6.8 | 6.8 | 2.3 | 2.3 | 2.2 | |
| 8012 | 8.0 | 8.0 | 1.1 | 3.4 | 2.4 | |
| 8015 | 8.0 | 8.0 | 1.35 | 3.4 | 2.4 | |
| 8020 | 8.0 | 8.0 | 1.8 | 3.2 | 2.4 | |
| 1028 | 10.0 | 10.0 | 2.8 | 4.2 | 7.4 | |
| 1038 | 10.0 | 10.0 | 3.8 | 4.2 | 7.4 |
Rated current typ. referring to 40 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 40 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 40 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 10% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 40 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 40 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 40 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Rated current typ. referring to 30 K heating above ambient temperature. Saturation current typ. referring to inductance loss of 35% typ.
Please contact our 24h eMail hotline for questions and feedback