Design Kit Common Mode Power Line Chokes WE-CMB

Order Code: 744820

Characteristics:

  • Sample kit contains 30 components of the Current Compensated Chokes
    WE-CMB Typ XS, S, M, L, XL sowie WE-CMB NiZn Typ XS
  • Inductance values from 14 µH to 39 mH
  • 6 types, 30 values and 80 components in one sample case
  • Free refill

Electrical properties

WE-CMB NiZn XS 
Order Code Inductance
(µH)
Tolerance Inductance
Rated Current
(A)
DC Resistance
(mΩ)
Operating Voltage
Coil Ratio
Design
Insulation Test Voltage
Description
744841414 14±30%4.015250 V AC2THT1.5 kV ACWE-CMB NiZn Common Mode Power Line Choke
744841330 30±30%3.026250 V AC2THT1.5 kV ACWE-CMB NiZn Common Mode Power Line Choke
744841247 47±30%2.040250 V AC2THT1.5 kV ACWE-CMB NiZn Common Mode Power Line Choke
744841210 100±30%1.580250 V AC2THT1.5 kV ACWE-CMB NiZn Common Mode Power Line Choke

Electrical properties

WE-CMB XS 
Order Code Inductance
(µH)
Tolerance Inductance
Rated Current
(A)
DC Resistance
(mΩ)
Operating Voltage
Coil Ratio
Design
Insulation Test Voltage
Description
744821201 1±30%2.044.5250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744821240 4±30%1.5140250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744821150 5±30%1.0200250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744821110 10±30%0.7350250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744821120 20±30%0.51000250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744821039 39±30%0.33000250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke

Electrical properties

WE-CMB S 
Order Code Inductance
(µH)
Tolerance Inductance
Rated Current
(A)
DC Resistance
(mΩ)
Operating Voltage
Coil Ratio
Design
Insulation Test Voltage
Description
744822301 1.0±30%3.035250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744822222 2.2±30%2.070250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744822233 3.3±30%1.5120250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744822110 10±30%1.0360250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744822120 20±30%0.5540250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke

Electrical properties

WE-CMB M 
Order Code Inductance
(µH)
Tolerance Inductance
Rated Current
(A)
DC Resistance
(mΩ)
Operating Voltage
Coil Ratio
Design
Insulation Test Voltage
Description
744823601 1.0±30%6.013250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744823422 2.2±30%4.030250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744823333 3.3±30%2.560250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744823210 10±30%2.0125250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744823220 20±30%1.5270250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke

Electrical properties

WE-CMB L 
Order Code Inductance
(µH)
Tolerance Inductance
Rated Current
(A)
DC Resistance
(mΩ)
Operating Voltage
Coil Ratio
Design
Insulation Test Voltage
Description
744824101 1.0±30%10.07250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744824622 2.2±30%6.020250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744824433 3.3±30%4.035250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744824310 10±30%3.0105250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744824220 20±30%2.0220250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke

Electrical properties

WE-CMB XL 
Order Code Inductance
(µH)
Tolerance Inductance
Rated Current
(A)
DC Resistance
(mΩ)
Operating Voltage
Coil Ratio
Design
Insulation Test Voltage
Description
7448251201 1.0±30%12.09250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
7448258022 2.2±30%8.014250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
7448256033 3.3±30%6.025250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744825510 10±30%5.055250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke
744825320 20±30%3.0160250 V AC2THT1.5 kV ACWE-CMB Common Mode Power Line Choke

Subject to changes, Version 1.0

To Parameter Search

Please contact our 24h eMail hotline for questions and feedback